Product name: Online Low Frequency UPS
Model: BG1KL / BG2KL / BG3KL / BG4KL / BG6KL / BG10KL
Rating: 1kVA-10kVA single phase, tower type
Key features:
Rating: 1kVA-10kVA single phase, tower type
Key features:
True online double conversion technology
With isolated transformer at output
IGBT inverter design
Wide input voltage range
Zero transfer time With SPWN –sine wave pulse width modulation
Generator compatible
Cold start feature (DC power on)
Automatically charging in OFF mode
Lighting and surge protections
Short-circuit and overload protections
EMI/RFI noise filter available
Extendable battery pack
Smart RS232
Intelligent slot interface(SNMP optional)
Application
Servers, Data centers, Critical network devices, computer rooms,banks,medical equipment, ISP, tele-communication
Technical specification
Model |
BG1KL |
BG2KL |
BG3KL |
BG4KL |
BG6KL |
BG10KL | |||||
Rated Power (VA/W) |
1kVA
(700W) |
2kVA
(1.4kW) |
3kVA
(2.1kW) |
4kVA
(2.8kW) |
6kVA
(4.2kW) |
10kVA
(7kW) | |||||
Input |
Nominal Voltage |
220/230/110/120VAC | |||||||||
Voltage Range |
220/230/110/120VAC ± 20% | ||||||||||
Frequency Range |
50/60Hz ± 5% | ||||||||||
Connection |
Terminal (hard wired) | ||||||||||
Output |
Voltage |
220/230/110/120VAC ± 1% | |||||||||
Frequency |
50/60Hz ± 0.5% | ||||||||||
Waveform |
Pure Sine Wave | ||||||||||
Power Factor |
0.7 | ||||||||||
Voltage Distortion |
2%-3% under linear load | ||||||||||
Overload Capability |
125% for one min;150% for 1s | ||||||||||
Crest Ratio |
3:1 max. | ||||||||||
Connection |
Terminal (hard wired) | ||||||||||
Battery |
Type |
VRLA battery for external battery pack | |||||||||
DC Voltage |
48V |
192VDC | |||||||||
Charge Current |
5A | ||||||||||
Recharge Time |
8 hours to 90% of capacity after full load discharge | ||||||||||
Transfer Time |
0 ms | ||||||||||
Effiency |
>85% | ||||||||||
Display |
LCD | ||||||||||
Protection |
Lightening and surge protection; short-circuit and overload protection | ||||||||||
LED Indicators |
AC,inverter,battery low,bypass,fault | ||||||||||
LCD Indicators |
AC input/output voltage/frequency;inverter,load level; Battery level;faulty | ||||||||||
Audible
alarm |
Bypass |
Alarm beeps every two minutes | |||||||||
Battery Low |
every second if battery low | ||||||||||
Overload |
Alarm beeps two for every second | ||||||||||
Fault |
Alarm beeps continuously | ||||||||||
Acoustic Noise |
≤60 dB | ||||||||||
Communications |
RS232 available; SNMP optional | ||||||||||
Working Temperature |
0 ~ 40°C | ||||||||||
Working Humidity |
0% ~ 95% non-condensing | ||||||||||
Gross Weight(kg) |
40kg |
62kg |
74kg |
76kg |
80kg |
122kg | |||||
UPS Dimension
W x D x H (mm) |
210*500*505 |
210*580*540 |
240*540*580 |
310*585*870 | |||||||
Packing Dimension
W x D x H (mm) |
315*590*600 |
664*315*625 |
700*360*670 |
580*780*1070 |
Note:
1.All models are without internal battery; they should be connected with external battery pack;
1.All models are without internal battery; they should be connected with external battery pack;
2.Custom-made specifications are acceptable;
3.All specification is subject to change without prior notice. BACK