Model: NGR1K / NGR2K / NGR3K / NGR6K / NGR10K
Rating: 1kVA-10kVA single phase, rack mount
Key features:
True online double conversion technology
Wide input voltage range
Zero transfer time
Advanced PFC technology
N+1 parallel redundancy function(6/10kVA)
Cold start feature (DC power on)
Automatically charging in OFF mode
Fan speed auto control when loads varies
Lighting and surge protections
Short-circuit and overload protections
Guaranteed output quality even with typical distorting IT loads
Low impact on mains supply with the IPF near to 1
Optional extendable battery pack
EMI/RFI noise filter available
Smart RS232
Intelligent interface(SNMP/AS400 optional)
LED or LCD display optional
Sealed lead Acid maintenance free battery
Rating: 1kVA-10kVA single phase, rack mount
Key features:


















Application
Servers, Data centers, Critical network devices, computer rooms, telecom and banks ect..
Technical specification
Model |
NGR1K/1KL |
NGR2K/2KL |
NGR3K/3KL |
NGR6K/6KL |
NGR10K/10KL | |
Rated Power (VA/W) |
1kVA/700W |
2kVA/1.4kW |
3kVA/2.1kW |
6kVA/4.2kW |
10kVA/7kW | |
Input |
Nominal Voltage |
220/230/110/120VAC | ||||
Voltage Range |
115~300VAC/60~138VAC |
176~276VAC/70~130VAC | ||||
Frequency Range |
46~54Hz(default);user adjustable within 40~60Hz | |||||
Power Factor |
0.97 | |||||
Connection |
IEC input socket |
Terminal(hard wired) | ||||
Output |
Voltage |
220/230/110/120VAC ±2% |
220/230/110/120VAC ±1% | |||
Frequency |
50/60Hz ±0.2Hz | |||||
Waveform |
Pure Sine Wave | |||||
Power Factor |
0.7 | |||||
VoltageDistortion |
3% under linear load | |||||
Overload
Capability |
110%~150% switch to bypass after 30 seconds; ±150% for 300ms |
105%~130% for 10min; 130% for 1min | ||||
Crest Ratio |
3:1 max. | |||||
Connection |
Output sockets (optional) |
Terminal | ||||
Bypass |
Autotransfer |
on when overload or UPS fails | ||||
Before UPS On |
Default “NO’; user adjustable to “YES” | |||||
Battery |
Type |
VRLA battery | ||||
Quantity |
3*7AH internal |
8*7AH battery pack |
20*7AH battery pack | |||
Charging Current |
1-3KVA,1A/8A for L model; 6-10KVA,1A/4.2A for “L” model | |||||
Recharge Time |
5 hrs to 90% of capacity after full load discharge | |||||
Transfer Time |
0 ms | |||||
Display |
LED or LCD optional | |||||
Protection |
Lightening and surge protection; short-circuit and overload protection;over/low voltage protection | |||||
LED Indicators |
Normal(green); warning(yellow);fault(red) | |||||
LCD Indicators |
AC input/output voltage/frequency;inverter,load level; Battery level; bypass,faulty | |||||
Audible
Alarm |
Battery Mode |
beeps every four seconds | ||||
Battery Low |
Beeps every second | |||||
Overload |
beeps twice every second | |||||
Bypass |
Beeps every two minutes | |||||
Fault |
beeps continuously | |||||
Acoustic Noise |
≤55 dB | |||||
Communications |
RS232 available; USB or AS400 or SNMP optional | |||||
Working Temperature |
0 ~ 40°C | |||||
Working Humidity |
20% ~ 90% non-condensing | |||||
Gross Weight(kg) |
16/9 |
38/12 |
39/17 |
115/55 |
119/58 | |
UPS Dimension
W x D x H (mm) |
482*420*87 |
487*600*130 | ||||
Packing Dimension
W x D x H (mm) |
610*590*280 |
790*600*330 |
Note:
1. “L” Model means model with long backup model without battery inside;
2.Custom-made specifications are acceptable;
3.All specification is subject to change without prior notice.
BACK
1. “L” Model means model with long backup model without battery inside;
2.Custom-made specifications are acceptable;
3.All specification is subject to change without prior notice.